|
1kV extruded insulated power cable
Collect
商品说明
The 1kV extruded insulated power cable produced by Shandong Yanggu Cable Group is fixedly laid on transmission and distribution lines with AC 50Hz and rated voltage of 1kv and below for transmitting electric energy. The laying method can be buried underground, in the air, on a bridge, etc. 1. Product execution standards 1. GB/T 12706.1-2008 Extruded insulated power cables and accessories with rated voltage 1kV (Um=1.2kV) to 35kV (Um=40.5kV) Part 1: Rated voltage 1kV (Um=1.2kV) and 3kV (Um= 3.6kV) cable 2. GB/T 19666-2005 General rules for flame-retardant and fire-resistant cables (only applicable to flame-retardant and fire-resistant cables) 2. Product characteristics 1. Conditions of use Rated working voltage: 0.6/1 (1.2) kV; Cable laying temperature: ≥0℃; The maximum allowable long-term operating temperature of cable conductors: PVC insulation: 70℃, XLPE insulation: 90℃; The maximum working temperature of the cable during short circuit (maximum 5s): XLPE insulation 250℃; PVC insulation: cross-sectional area ≤ 300mm², 160℃, cross-sectional area > 300mm², 140℃; The minimum allowable bending radius of the cable: single-core unarmored 20D, single-core armored 15D, three-core unarmored 15D, three-core armored 12D. Note: D is the actual outer diameter of the cable. 2. Structural requirements The basic structure of 1kV extruded insulated power cable consists of three parts: conductor, insulation layer and protective layer. 1) conductor The conductor is made of twisted copper wire or aluminum wire and meets the requirements of GB/T 3956-2008 standard. Conductors are the conductive parts of power cables used to carry electrical energy 2) Insulation Insulation is extruded PVC or XLPE. Electrically isolate the wire core from the earth and wire cores of different phases to ensure power transmission. 3) Outer sheath The outer sheath is PE or PVC, and flame retardant, termite-proof, low-smoke low-halogen flame-retardant, low-smoke halogen-free flame retardant and other materials can also be provided according to customer requirements. Its function is to protect the power cable from the intrusion of external impurities and moisture, and to prevent direct damage to the power cable by external forces. 3. The structural diagram of 1kV extruded insulated power cable is as follows.
4. Model description of 1kV extruded insulated power cable Product code (omitted) Characteristic code WDZ - low smoke halogen-free flame retardant; ZA (ZB, ZC) - flame retardant (A, B, C) level; NH - fire resistant; Conductor material code Type 2 copper conductor - (T) omitted; Type 5 copper conductor - R; Aluminum conductor - L Insulation material code YJ-cross-linked polyethylene insulation; V-polyvinyl chloride insulation; E-ethylene propylene rubber insulation; EY-hard ethylene propylene rubber insulation Sheath material code V-polyvinyl chloride sheath; Y-polyethylene or polyolefin sheath; F-elastomer sheath; Q-lead sheath Armor material code 2-Double steel tape armor; 3-Fine round steel wire armor; 4-Thick round steel wire armor; 6-(Double) non-magnetic metal tape armor; 7-Non-magnetic metal wire armor Outer sheath material code 2-Polyvinyl chloride sheath; 3-Polyethylene or polyolefin sheath; 4-Elastomer sheath Common models
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||

