Model | The name of the cable | Model description |
JL
| Stranded aluminum | J-Concentric stranded F-Anti-corrosion L-Hard round aluminum wire (LY9 type) G-galvanized steel wire for stranded wire (G1A type, G1B type, G2A type, G2B type, of which: 1-Ordinary strength 2-High strength A-Ordinary coating thickness B- Thickened coating thickness |
JL/G1A | Type A ordinary strength steel core aluminum stranded wire |
JL/G1B | Type B ordinary strength steel core aluminum stranded wire |
JL/G2A | A-type high-strength steel-core aluminum stranded wire |
JL/G2B | Type B high-strength steel-core aluminum stranded wire |
JL/G3A | Ultra-high-strength grade steel-core aluminum stranded wire |
JL/G1AF | Ordinary strength anti-corrosion steel core aluminum stranded wire |
JL/G2AF | High-strength anti-corrosion steel core aluminum stranded wire |
Model | The name of the cable | Note:LHA2 is a high-strength aluminum alloy wire corresponding to 53% IACS. LHA1 is a high-strength aluminum alloy stranded wire corresponding to 52.5% IACS. LHA3 is a medium-strength aluminum alloy stranded wire corresponding to 58.5% L1-L4 is a conductivity of (61.5%, IACS-63%) IACS) cables |
JLHA2 JLHA1 JLHA3 | Aluminum alloy stranded wire |
JL/LHA2 JL/LHA1 | Aluminum alloy core aluminum stranded wire |
JL1/LHA1 JL2/LHA1 JL3/LHA1 JL4/LHA1 | Aluminum alloy core high conductivity aluminum stranded wire |
JLHA2/ G1A JLHA1/G1A | Steel-core aluminum alloy stranded wire |
JLHA2/LB1A JLHA1/LB1A | Aluminum-clad steel core aluminum alloy stranded wire |
Aluminum alloy stranded wire, aluminum alloy core aluminum stranded wire, steel core aluminum stranded wire Product Introduction With the improvement of transmission technology and the development of power transmission and transformation lines, the advantages of aluminum-magnesium-silicon high-strength aluminum alloy series stranded wire are becoming more and more obvious. Advantages: - High strength, light weight, small sag sag, can increase the distance of the tower or reduce the height of the tower, reduce land occupation and line construction costs. —Aluminum alloy surface is hard, anti-extrusion, easy to connect wires, high construction efficiency, not easy to wear and scratch during erection, can reduce corona loss, reduce transmission line interference to radio waves - Good creep resistance - Corrosion resistance and long service life Execution Standard High-strength aluminum alloy wire execution JB/ T8134-1997 standard (equivalent to IEC60104:1987 standard) Aluminum alloy core aluminum stranded wire implements GB/T17048-1997 standard (equivalent to IEC60889:1987 standard) Galvanized steel wire with steel core aluminum alloy stranded wire implements GB/T3428-2012 standard (equivalent to IEC60888:1987 standard). The product implements the 1179-2008 standard |
Heat-resistant aluminum alloy stranded wire and high-strength steel core heat-resistant aluminum alloy stranded wire |
Model | The name of the cable |
NRLH58J NRLH60J | Heat-resistant aluminum alloy stranded wire |
NRLH58GJ NRLH60GJ | Steel core heat-resistant aluminum alloy stranded wire |
Product Introduction Heat-resistant aluminum alloy stranded wire and high-strength steel core heat-resistant aluminum alloy stranded wire are wires made of heat-resistant aluminum alloy round wire and high-strength galvanized steel strand. With the rapid development of the national economy and the continuous improvement of the people's level, the demand for electricity has increased sharply, and the transmission line is increasingly developing to large capacity, which requires increasing the transmission capacity of the conductor. As a special wire with good performance, heat-resistant aluminum alloy has good advantages in China's urban network transformation, substation construction and general lines. Features: 1. The long-term working temperature is 150 °C, and the short-term temperature can reach 180 °C, so that the continuous allowable current carrying capacity is 1.5-1.6 times that of ordinary wire of the same specification 2. It has the same strength as ordinary stranded wire at room temperature, and the strength is kept above 90% when running at high temperature. 3. No matter at room temperature or high temperature, it maintains the same degree of creep resistance compared with ordinary aluminum wire. 4. There is no big difference between the laboratory smoke test and the outdoor atmosphere exposure test. Occasions of use: 1. It is especially suitable for high-current transmission bus in substations and power plants. It can save engineering investment. 2. In the urban network line expansion and reconstruction project, especially in the narrow area of the line corridor, only need to replace the conductor with similar cross-sectional specifications, and basically do not need to replace the tower, which can meet the strength and the relaxation requirements of the conductor to the ground. 3. In the double-circuit circuit, it can also carry the current carrying capacity of the other circuit for a short time, which is convenient for emergency repair and maintenance in the event of an accident in the circuit. 4. On the new line, the use of heat-resistant aluminum alloy wire simplifies the line structure, which has great benefits for the safe operation of the line. Executive standards: 1. Heat-resistant aluminum alloy stranded wire and heat-resistant aluminum alloy round wire with high-strength heat-resistant aluminum alloy stranded wire shall implement the Q/ZJ3-2008 standard 2. High-strength galvanized steel wire with heat-resistant aluminum alloy stranded wire shall be implemented according to the standard GB/T3428-2012 standard (equivalent to the IEC60888: 1987
Heat-resistant aluminum alloy wire products implement Q/ZJ4-2008 |
|